Baitong Kexin
Contact

EV High-Voltage Safety Simulation Trainer

Model: BT-GYAQ-001

Practice EV isolation reasoning and interlock checks with the BT-GYAQ-001 safety trainer using physical connectors and simulated electrical values.

EV High-Voltage Safety Simulation Trainer

EV High-Voltage Safety Simulation Trainer
Input supply
220 V, 50 Hz
Simulated circuit operating voltage
≤20 V
Simulated voltage range
5–2,000 V; not the physical output rating
Fault points
≥60

The 5–2,000 V range is a simulated display value, not the physical output of the trainer. The simulated circuit operates at low voltage while the workstation uses the stated mains input supply.

Request This Configuration
On This Page Overview

Product Overview

The Baitongkexin BT-GYAQ-001 is a simulation trainer for introducing EV high-voltage safety concepts before supervised work on actual vehicle systems. Physical connectors and a service-disconnect arrangement are combined with simulated voltage, insulation and fault conditions. The control logic can recognize selected connection and isolation steps and display feedback. Instructors can use this feedback to discuss a learner’s sequence and reasoning without treating simulation completion as authorization for live high-voltage work.

Course areas: EV high-voltage safety fundamentals, Simulated isolation and verification procedures, High-voltage interlock and insulation-fault reasoning, AC charging safety simulation.

Core Functions

Physical Actions with Simulated Conditions

Learners use designated connectors and test interfaces to investigate simulated interlock and insulation conditions. The teaching scope also covers precharge and equipotential protection principles. Displayed high-voltage values are simulation values.

Feedback on the Selected Sequence

The built-in logic monitors specified connections and isolation steps, showing incorrect steps and fault-clearance results. This supports instructor review of the simulated task.

Several Fault Teaching Areas

The configuration covers battery and high-voltage safety topics together with an AC charging simulation and handheld diagnostic-simulation interface.

Practical Training Tasks

  1. Isolation sequence

    Learner Practice

    Complete an instructor-approved simulated isolation task

    Evidence for Review

    A step record and explanation of the displayed feedback

  2. Circuit interpretation

    Learner Practice

    Investigate a simulated interlock or insulation condition

    Evidence for Review

    A reading-based explanation of the represented fault

  3. Charging safety

    Learner Practice

    Analyze a selected AC charging simulation case

    Evidence for Review

    A distinction between the simulated result and a real installation test

Equipment and Scope

  • Simulation and Connection Bench

    The bench uses low-voltage data acquisition and control logic to represent high-voltage circuit states, interlock behavior, insulation conditions and selected fault scenarios.

  • Physical Safety Interfaces

    The platform provides a charging socket, high-voltage-style connectors, a busbar, a service disconnect and 4 mm connection points for supervised connection and isolation exercises.

  • Measurement and Diagnostic Interfaces

    Reserved measurement points, a display interface and a handheld touchscreen diagnostic-simulation interface support guided measurement, operating-sequence review and fault-clearance feedback.

Technical Specifications

The 5–2,000 V range is a simulated display value, not the physical output of the trainer. The simulated circuit operates at low voltage while the workstation uses the stated mains input supply.

EV High-Voltage Safety Simulation Trainer — Technical Specifications
Input supply220 V, 50 Hz
Simulated circuit operating voltage≤20 V
Simulated voltage range5–2,000 V; not the physical output rating
Fault points≥60
Measurement-point groups≥70
Measurement combinations≥100
AC charging simulation≥8 fault cases

Configuration and Ordering

Reference Laboratory Quantity

1 unit

This quantity belongs to the reference laboratory equipment schedule. Confirm the quantity for your project in the quotation.

Configuration and Procurement

Specify the local training framework and practical tasks. Obtain a verified electrical schedule separating simulated values from accessible outputs. The trainer supports foundational teaching; workplace authorization and formal certification depend on applicable requirements and qualified assessment.

Details for Your Inquiry

Share the safety curriculum, learner level and local requirements to review the simulated tasks and confirmed electrical limits.

Product Questions

Does the trainer output 2,000 V?

The 5–2,000 V range describes simulated values, not a physical high-voltage output. The actual electrical limits must be confirmed in the equipment documentation.

Does completion qualify a student for high-voltage work?

No. A simulation exercise supports learning but does not replace the required practical training, institutional authorization or local qualification process.