Eight-Channel Battery Cell Grading and Test Unit

Model: BT-BD02

Compare battery cell capacity using the eight-channel BT-BD02 test unit, four-wire acquisition and defined charge-discharge operating limits.

Eight-Channel Battery Cell Grading and Test Unit

Eight-Channel Battery Cell Grading and Test Unit
Independent channels
8
Charge voltage at ports
10 mV–5 V
Discharge voltage at ports
1–5 V; lower limit depends on lead arrangement
Charge/discharge current
20 mA–10 A
Request This Configuration
On This Page Overview

Product Overview

The Baitongkexin BT-BD02 is a cell-level charge-discharge and grading unit for battery teaching and preparation work. Eight independent channels use four-wire current and voltage acquisition to record individual cell behavior. Instructors can use the results to teach capacity comparison, test consistency and cell selection. The unit tests cells within its specified channel limits; it is not a high-voltage pack tester or a guarantee that a selected group is suitable for assembly.

Core Functions

Independent Cell Channels

Each channel supports its own cell test, allowing learners to compare results from a defined batch under a consistent procedure. The fixture and test profile must suit the cell chemistry and terminals.

Several Test Modes

Charge modes include constant current, constant voltage, combined constant current/constant voltage and constant power. Discharge modes include constant current, constant power and constant resistance.

Recorded Results for Comparison

The PC software provides charge-discharge records. Learners can compare voltage, current and capacity results and explain why test conditions matter when grouping cells.

Practical Training Tasks

  1. Test planning

    Learner Practice

    Choose an approved cell profile within channel limits

    Evidence for Review

    A documented profile and cell identification record

  2. Capacity comparison

    Learner Practice

    Run a supervised test on a selected batch

    Evidence for Review

    A comparison of channel results under stated conditions

  3. Grading decisions

    Learner Practice

    Review measured results against instructor criteria

    Evidence for Review

    A justified grouping decision, not an automatic pack-safety approval

Equipment and Scope

The configuration includes an eight-channel unit, copper crocodile-clip fixtures and PC test software. Confirm the host computer, fixture suitability, calibration documents and any export or reporting options.

Technical Specifications

Eight-Channel Battery Cell Grading and Test Unit — Technical Specifications
Independent channels8
Charge voltage at ports10 mV–5 V
Discharge voltage at ports1–5 V; lower limit depends on lead arrangement
Charge/discharge current20 mA–10 A
Power per channel50 W
Data recording frequency1 Hz
Reference dimensions500 × 450 × 150 mm

Configuration and Ordering

Reference Laboratory Quantity

1 unit

This quantity belongs to the reference laboratory equipment schedule. Confirm the quantity for your project in the quotation.

Configuration and Procurement

Provide the cell chemistry, format, terminal arrangement and intended test profile. Confirm how voltage, current and power limits interact, plus the applicable accuracy specification and calibration conditions. Compatibility should be documented for the exact cell type rather than inferred from a form factor such as 18650.

Details for Your Inquiry

Provide cell chemistry, format, terminals and intended test profiles to specify fixtures, software and the host-computer package.

Product Questions

Can it test an assembled EV battery pack?

No. The listed channels are for low-voltage cell testing within their individual limits. A pack requires appropriately rated test equipment.

Is a computer supplied?